Carbon Tower
SÜMER Activated Carbon Tower
 

SÜMER CT series activated carbon adsorbers are perfect choice when it comes to delivering a continuous supply of high-quality compressed air. Any remaining oil-aerosols and oil vapors, including odors and tastes, are removed by the active surface area of the highly-porous activated carbon to produce high quality and clean compressed air.

Installed downstream of compressed air drying and pre-filtration components, they attain Class 1 (no higher than 0.01 mg/m³) residual oil content as per ISO 8573-1 to ensure dependable protection of sensitive production processes. They are therefore, the perfect choice for applications in the optical, surface technology, electronics, foodstuffs and pharmaceutical sectors.

SÜMER Carbon Towers are compact and designed to be free standing units and it does not need any maintenance. Pre-dried compressed air flows from top to bottom through a single vessel containing high-quality CarboTech activated carbon. Finally, the treated compressed air exits an after filter rated for solid particulates removal into the downstream compressed air network with an oil content of less than 0.003 mg/m3.

Generously-dimensioned flow diameters, together with flow diffusers, ensure even flow distribution with an exceptionally low-pressure loss no higher than 0.1 bar. As a result, the compressor discharge pressure of upstream compressors, as well as the energy costs for compressed air production, can be kept as low as possible.

The lifetime of the activated carbon filling can vary and is dependent on the contamination type, quantity, and the relative humidity of the supplied compressed air. However, the adsorber bed can last up to an excess of 10,000 working hours when properly maintained.

Benefits/Features
 

Low maintenance
Separate fill and drain ports allow for quicker carbon replacement
Standalone units
Includes pressure gauge
PED coded vessel

Typical Applications
 

Food and beverage
Pharmaceutical - manufacturing and processing
PSA processes
Membrane processes
Breathable Air/Oxygen
Anywhere air purity is critical

 

 

Product Specification
 

Ordering and Performance Data

Model Flow Rate m 3 /h Port Size Max Pressure bar (g) Max Temp. °C Activated Carbon Amount (kg)
CT-120 120 3/4" 16 50 12
CT-250 250 1" 16 50 25
CT-375 375 1 ½ " 16 50 38
CT-500 500 1 ½ " 16 50 50
CT-750 750 2" 16 50 75
CT-1000 1.000 2" 16 50 100
CT-1500 1.500 2 ½" 16 50 150
CT-2000 2.000 3" 16 50 200
CT-2500 2.500 3" 16 50 250

Note-1: For larger flow rates, please consult factory.
Note-2: ISO 8573-1:2010 Class 1 met when recommended filtration is used.

 

Recommended Filtration Requirements

Pre-filter ISO8573-1:2010 Class 1.4.1
0.01 micron (W-P-G)
0.01 mg/m3 oil carryover (H)
At least +3 degree pressure dew point
After-filter Solid particulates 1.0 micron (D)

 

Operating Range

Site Selection Frost-free indoor installation in a non-hazardous environment
Ambient Temperature 2 to 50°C
Maximum Compressed Air Inlet Temperature 50°C
Maximum Operating Pressure 16 bar(g)
Medium Compressed air and gaseous nitrogen

 

Materials of Construction

Pressure Vessels Normal steel, welded, Painted, PED
Adsorbing Material 100% Activated Carbon

 

Dimensions and Weight

Model Height (mm) Width (mm) Weight (kg)
CT-120 1.100 300 37
CT-250 1.000 350 65
CT-375 1.350 350 85
CT-500 1.600 350 108
CT-750 1.600 425 143
CT-1000 2.100 425 190
CT-1500 2.000 550 265
CT-2000 1.900 650 360
CT-2500 2.150 650 440

Correction Factors

Pressure Temperature
psi bar 35°C ( 95°F) 40°C ( 104°F ) 45°C (113°F) 50°C (122°F )
73 5 0.75 0.64 0.56 0.38
87 6 0.89 0.76 0.67 0.45
102 7 1.00 0.85 0.75 0.50
116 8 1.13 0.92 0.81 0.54
131 9 1.26 1.07 0.95 0.63
145 10 1.31 1.11 0.98 0.65
160 11 1.36 1.16 1.02 0.68
174 12 1.49 1.27 1.12 0.74
189 13 1.62 1.38 1.22 0.81
203 14 1.70 1.45 1.28 0.85
218 15 1.79 1.52 1.34 0.90
 